Transport

Collar EyeBolt To BS4278 Table 1




NOTES: All information on this page is for guidance only: For actual lifting capacities, dimensions and safe use requirements refer to the standards indicated and be advised by the equipment suppliers.  The safe working loads is for axial lifts only. For lifts not in line with axes of eyebolt the SWL has to be reduced.    Please refer to BS4278

Safe Working Load Metric Thread B C D E F G H J K L
tonnes dia mm mm mm mm mm mm mm mm mm mm
0.4 12 22 15 7 15 9 20 18 1 3 9
0.8 16 29 20 10 20 12 26 23 1 3 12
1.6 20 40 27 14 27 16 36 32 1 5 16
2.5 24 52 35 17 35 21 46 40 2 6 21
4.0 30 65 44 22 44 26 58 51 2 7 26
6.3 36 81 54 27 54 32 72 63 3 9 32
8.0 42 90 60 30 60 36 80 70 3 10 36
10.0 48 101 68 34 68 40 90 79 3 11 40
12.5 52 115 76 38 76 46 102 89 3 13 46
16.0 56 128 86 43 86 51 114 100 4 14 51
20.0 64 144 96 48 96 58 128 112 4 16 58
25.0 72 162 108 54 108 65 144 128 4 18 65
Lifting Index